Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Accuracy of CBCT in the Identification of Mental, Lingual, and Retromolar Foramina: A Comparison with Visual Inspection of Human Dry Mandibles
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 41 , Issue 6
November/December 2021

Pages e277–e286


Accuracy of CBCT in the Identification of Mental, Lingual, and Retromolar Foramina: A Comparison with Visual Inspection of Human Dry Mandibles


Fabio Savoldi, DDS, MDS, PhD/Madeline J. Y. Yon, BDS/Vincent M. K. Kwok, BDS/Andy W. K. Yeung, BDS, PhD/Ray Tanaka, DDS, PhD/James K. H. Tsoi, BSc, PhD/Jukka P. Matinlinna, BSc, MSc, PhD/Michael M. Bornstein, Prof Dr med dent


PMID: 34818398
DOI: 10.11607/prd.4770

The present dry-mandible study evaluated the presence of the mental (MF), lingual (LF), and retromolar (RMF) foramina to assess the accuracy of CBCT in detecting these anatomical structures. In total, 38 human dry mandibles were analyzed (30 men, 8 women; mean age: 61.9 ± 13.7 years). CBCT scans were taken using low-dose parameters, and LF, MF, and RMF were assessed visually and radiographically. Both the presence (yes/no) and the count (n) of each foramen were compared between CBCTs and visual assessment. For the presence assessment, only RMF exhibited a significant difference between CBCT and visual inspection (P = .035). For count, the RMF (P = .049) and paramedian LF (P = .003) exhibited differences between the two methods. The agreement between CBCT and visual inspection was excellent for the MF, moderate–excellent for the LF, and low–moderate for the RMF. Intra- and interassessor agreement varied from excellent (MF), to moderate–excellent (LF), and low–moderate (RMF). The LF and RMF represent challenging structures to identify on CBCT images due to their limited dimension. False negative findings in CBCTs in the assessment of foramina, especially LF, might lead to surgical complications during implant surgery.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help